C Arm System
The GE OEC 6800 MiniView is one of the most popular mini c-arms in the world – and for good reason. The OEC 6800 incorporates the workstation components of GE’s full-sized OEC 9800 Plus c-arm at a cost-effective price. The OEC 6800 MiniView is effectively used by hand surgeons, podiatrists, orthopedics and rehabilitation services.
The GE OEC 6800 MiniView is one of the most popular mini c-arms in the world – and for good reason. The OEC 6800 incorporates the workstation components of GE’s full-sized OEC 9800 Plus c-arm at a cost-effective price. The OEC 6800 MiniView is effectively used by hand surgeons, podiatrists, orthopedics and rehabilitation services. Features include:
- Superb Images – 50-micron focal spot captures the finest anatomical detail
- Immediate Results – Fully-digital 1k x 1k, 16-bit image processing with real-time edge enhancement
- Unsurpassed Viewing – 19-inch diagonal dual monitors and selectable image size provide a highly flexible viewing area
- Expanded Archiving – Up to 800 images saved in memory of 2000 images of removable media.
GE MiniView 6800 Specifications:
Base Dimensions
- Height: 65” (168.1 cm)
- Width: 27.75” (70.7 cm)
- Depth: 27.5” (70.7 cm)
C-Arm Extension
- Maximum Front: 54.5” (138.4 cm)
- Max. Height I.I. Up: 71.5” (181.6 cm)
- Min. Height I.I. Down: 5.5” (14 cm)
Transport Position
- Height: 65” (165.1 cm)
- Min. Width: 33.5” (85.1 cm)
- Min.Depth: 32.5” (82.6 cm)
Stability
- Positive stability on grade up to 5 degrees in any position.
- Positive stability on grades up to 10 degrees in the transport position.
Imaging Area
- Depth: 17.7” (44.95 cm)
- SID: 17.7” (44.95 cm)
- Free Space: 13.5” (34.27 cm)
- Skin Spacer: 3.9” (10 cm)
Movements
- Orbital Travel: 118 degrees
- Wig-Wag: 135 degrees
- Total Rotation ±200 degrees
Laser Aimer
- Dual Fan Beam Laser Diodes
- Laser Class IIIA
- Power Output: 5mW max.
- Wavelength: 650 nM
- Fan Beam Coverage: 7.87” (20 cm)
Image Intensifier
- Normal Nominal Entrance Field Size: 5.9” (15 cm)
- Mag Nominal Entrace Field Size: 3.94” (10 cm)
- Supply Input Voltage: 24 ± 1 VDC
- Input X-ray Exposure: 1 R/minute max.
- Central Resolution: 66 Lp/cm (typical)
- Contrast Ratio: 30:1 (typical)
- Coversion Factor: 180 cd/m2 (typical) mR/S
- DQE: 42%
Fluoroscopic Accuracy
- μΛ: ±5%
- kV: ±5%
X-Ray Source Assembly
- Type: Fixed anode, tungsten filament
- Target Angle: 14 degrees
- Focal Spot: 0.05 MM
- Inherent Filtration: 1.0 mm Al Equivalent
- Total Filtration: 2.5 mm Al Equivalent
- Beam Quality: Minimum HVI, 2.8 mm Al @ 80 kV
- Leakage Technique Factors: 80 kV and160 μA
Power
- Line Frequency: 60/50 Hz
- 100/120 VAC (±10%): 6 Amps
- 200/220/230/240 VAC (±10%): 4 Amps
- Max. Non-Descrtuctive voltages thatcan be connected to signal I/O ports: 7 Volts DC
- Room I/O Port: +24V relay closures, +5TTL logic levels
Video Signal
- Composite video, EIA RS170A 60 Hz, 525 line (International CCIR 50 Hz, 625 line)
Environmental Requirements
- Operating Temp.: 50 to 95°F (10 to35°C)
- Storage Temp.: +14 to 131°F (-10 to+55°C)
- Operating Altitude: 8,202 ft. (2.5 km)
- Storage Altitude: 15,000 ft. (4.6 km)
- Operating Humidity: 20 to 80% non-condensing
- Storage and Transport Humidity: 20 to 80% on-condensing.
- Shock and Vibration: 1G at 200 Hz for 2 hours.)
Image Processing and Storage
- CP Image Storage: 18
- HP Image Storage: 400
- Frame Integration: Yes
- Image Matrix Size: 1000 x 1000 x 16
- Last Image Hold: Yes
- Video storage digital memory PCMCIA drive, hard disk, floppy disk, SVHS VCR(optional)
Monitors
- Dual Monitors
- Monitor Size: 16” (40.64 cm)