C Arm System

In stock

The GE OEC 6800 MiniView is one of the most popular mini c-arms in the world – and for good reason. The OEC 6800 incorporates the workstation components of GE’s full-sized OEC 9800 Plus c-arm at a cost-effective price. The OEC 6800 MiniView is effectively used by hand surgeons, podiatrists, orthopedics and rehabilitation services.

The GE OEC 6800 MiniView is one of the most popular mini c-arms in the world – and for good reason. The OEC 6800 incorporates the workstation components of GE’s full-sized OEC 9800 Plus c-arm at a cost-effective price. The OEC 6800 MiniView is effectively used by hand surgeons, podiatrists, orthopedics and rehabilitation services. Features include:

  • Superb Images – 50-micron focal spot captures the finest anatomical detail
  • Immediate Results – Fully-digital 1k x 1k, 16-bit image processing with real-time edge enhancement
  • Unsurpassed Viewing – 19-inch diagonal dual monitors and selectable image size provide a highly flexible viewing area
  • Expanded Archiving – Up to 800 images saved in memory of 2000 images of removable media.

GE MiniView 6800 Specifications:

Base Dimensions

  • Height: 65” (168.1 cm)
  • Width: 27.75” (70.7 cm)
  • Depth: 27.5” (70.7 cm)

C-Arm Extension

  • Maximum Front: 54.5” (138.4 cm)
  • Max. Height I.I. Up: 71.5” (181.6 cm)
  • Min. Height I.I. Down: 5.5” (14 cm)

Transport Position

  • Height: 65” (165.1 cm)
  • Min. Width: 33.5” (85.1 cm)
  • Min.Depth: 32.5” (82.6 cm)

Stability

  • Positive stability on grade up to 5 degrees in any position.
  • Positive stability on grades up to 10 degrees in the transport position.

Imaging Area

  • Depth: 17.7” (44.95 cm)
  • SID: 17.7” (44.95 cm)
  • Free Space: 13.5” (34.27 cm)
  • Skin Spacer: 3.9” (10 cm)

Movements

  • Orbital Travel: 118 degrees
  • Wig-Wag: 135 degrees
  • Total Rotation ±200 degrees

Laser Aimer

  • Dual Fan Beam Laser Diodes
  • Laser Class IIIA
  • Power Output: 5mW max.
  • Wavelength: 650 nM
  • Fan Beam Coverage: 7.87” (20 cm)

Image Intensifier

  • Normal Nominal Entrance Field Size: 5.9” (15 cm)
  • Mag Nominal Entrace Field Size: 3.94” (10 cm)
  • Supply Input Voltage: 24 ± 1 VDC
  • Input X-ray Exposure: 1 R/minute max.
  • Central Resolution: 66 Lp/cm (typical)
  • Contrast Ratio: 30:1 (typical)
  • Coversion Factor: 180 cd/m2 (typical) mR/S
  • DQE: 42%

Fluoroscopic Accuracy

  • μΛ: ±5%
  • kV: ±5%

X-Ray Source Assembly

  • Type: Fixed anode, tungsten filament
  • Target Angle: 14 degrees
  • Focal Spot: 0.05 MM
  • Inherent Filtration: 1.0 mm Al Equivalent
  • Total Filtration: 2.5 mm Al Equivalent
  • Beam Quality: Minimum HVI, 2.8 mm Al @ 80 kV
  • Leakage Technique Factors: 80 kV and160 μA

Power

  • Line Frequency: 60/50 Hz
  • 100/120 VAC (±10%): 6 Amps
  • 200/220/230/240 VAC (±10%): 4 Amps
  • Max. Non-Descrtuctive voltages thatcan be connected to signal I/O ports: 7 Volts DC
  • Room I/O Port: +24V relay closures, +5TTL logic levels

Video Signal

  • Composite video, EIA RS170A 60 Hz, 525 line (International CCIR 50 Hz, 625 line)

Environmental Requirements

  • Operating Temp.: 50 to 95°F (10 to35°C)
  • Storage Temp.: +14 to 131°F (-10 to+55°C)
  • Operating Altitude: 8,202 ft. (2.5 km)
  • Storage Altitude: 15,000 ft. (4.6 km)
  • Operating Humidity: 20 to 80% non-condensing
  • Storage and Transport Humidity: 20 to 80% on-condensing.
  • Shock and Vibration: 1G at 200 Hz for 2 hours.)

Image Processing and Storage

  • CP Image Storage: 18
  • HP Image Storage: 400
  • Frame Integration: Yes
  • Image Matrix Size: 1000 x 1000 x 16
  • Last Image Hold: Yes
  • Video storage digital memory PCMCIA drive, hard disk, floppy disk, SVHS VCR(optional)

Monitors

  • Dual Monitors
  • Monitor Size: 16” (40.64 cm)

Additional information

Brand

G.E Medical

Model

OEC Miniview 6800

Be the first to review “C Arm System”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.